Built with anodized metal enclosures for optimal thermal dissipation, electromagnetic compatibility (EMC EN 55032 Class B), and rigorous 100% full-load aging.
In the global precision landscape, Swiss manufacturing represents the pinnacle of tolerance, zero-defect philosophies, and long-term durability. Yueqing Keldan Technology Co., Ltd. supplies high-spec metal case power supplies tailored directly to Swiss engineering requirements.
The Swiss industrial equipment market—spanning machine tools, watchmaking assembly lines, laboratory automation, and rail infrastructure—operates under stringent operating environments. When power conversion occurs inside tightly sealed IP54 or IP65 stainless steel cabinets common in Swiss cleanrooms and workshops, heat dissipation cannot rely on loud, vulnerable internal fans.
Our enclosed perforated metal and extruded aluminum chassis serve a dual critical purpose: conducting heat away from sensitive power MOSFETs and electrolytic capacitors via passive convection, and creating an electromagnetic Faraday shield. This design guarantees low ripple, excellent conducted and radiated emission suppression (EN 55032 Class B), and protection against mechanical shock and vibration (IEC 60068-2-6).
Every metal-enclosed power supply exported to Switzerland is built to conform with Swiss and harmonized European frameworks:
Swiss engineers demand power supplies with unwavering mean time between failures (MTBF), low acoustic noise, and rock-solid transient response.
In the Jura Arc (Neuchâtel, Jura, Bernese Jura), high-speed multi-axis CNC machines and wire Electrical Discharge Machining (EDM) systems require ripple-free DC power. Our LRS-150-24 and S-350-24 enclosed power supplies prevent electrical noise from disturbing sub-micron linear encoders and high-frequency servo drives.
Watch Valley & MicrotechnologyBasel's pharmaceutical cluster relies on automated liquid handlers, bio-reactors, and spectrometry. Our metal case DIN-rail power units (EDR-120 and EDR-240) fit into stainless steel control enclosures, offering galvanic isolation up to 3000VAC, preventing ground loops, and resisting harsh decontamination washes.
Basel-Stadt / Basel-LandschaftRailways (SBB/CFF/FFS, RhB) and mountain tunnel monitoring networks operate under extreme thermal fluctuations (-20°C to +70°C) and heavy electromagnetic transients from overhead catenary wires. With high dielectric withstand ratings and TS35 vibration-proof latches, our DIN rail units power signaling nodes and PLC telemetry reliably.
Graubünden, Uri & ValaisSwitzerland's pumped-storage hydropower stations and distributed municipal utilities require resilient auxiliary 24V DC backbones. Our active PFC units eliminate unwanted reactive currents, enabling seamless interfacing with battery-backed UPS circuits and Modbus/PROFINET industrial communications.
Ticino & Central SwitzerlandHigh-power industrial fiber laser cutting heads and metal 3D printers in Zurich and Aargau machinery plants demand robust, peak-load sustaining DC power. Our 1000W and 3000W adjustable high-power converters deliver stable current regulation without sagging during laser pulse excitation.
Zurich & Aargau High-Tech BeltResearch facilities (EPFL, ETH Zurich, CERN partner labs) require flexible, highly stabilized variable laboratory sources. The 3000W benchtop variable source provides analog and remote-controlled CC/CV modes, ensuring clean test currents for cryogenic cooling test benches and electromagnet coils.
Vaud, Geneva & ZurichSwiss technical buyers are transitioning away from unbranded generic suppliers in favor of transparent, auditable manufacturers that support the Swiss Energy Strategy 2050.
Swiss grid operators (such as Swissgrid and cantonal cantonal distribution networks like BKW, EKZ) maintain strict network harmonics compliance. Power supplies drawing more than 75W must feature Active Power Factor Correction (PF > 0.95), preventing harmonic pollution (EN 61000-3-2) in densely equipped smart factories.
Conforming with the Swiss Energy Efficiency Ordinance (EnEV), Swiss OEMs prioritize units with no-load power consumption below 0.3W–0.5W and operating efficiencies exceeding 90–93%. Minimizing thermal waste directly reduces cabinet climate control energy bills.
Real estate inside Swiss control cabinets is at a premium. The shift toward ultra-slim (32mm–40mm width for 120W; 63mm for 240W) DIN rail metal modules allows electrical engineers to fit additional safety relays, contactors, and IoT gateways onto the same standard 35mm mounting rail.
Evaluate form-factor parameters to determine the correct topology for your machinery enclosures.
| Architecture Type | Typical Power | Cooling Mode | EMC Shielding | Swiss Industry Application Fit | Mounting Method |
|---|---|---|---|---|---|
| Slim DIN Rail (EDR/NDR Series) | 75W – 480W | Free Air Convection | ✔ High (EN 55032 B) | PLC cabinets, smart building automation, rail trackside | Snap-on TS-35/7.5 or TS-35/15 |
| Low-Profile Enclosed (LRS Series) | 35W – 350W | Passive Perforated Case | ✔ Medium-High | Internal machinery, 3D printing, laser marking, CCTV hubs | Chassis screw mounting (1U height) |
| Heavy Enclosed Switching (S Series) | 250W – 600W | Internal Fan / Passive | ✔ High | High-load stepper motors, CNC routers, industrial heaters | Flange / baseplate direct mount |
| High-Power Variable Benchtop | 1000W – 3000W | Intelligent Forced Air | ✔ Laboratory Grade | R&D prototypes, electroplating, anodizing, battery testing | Desktop / 19-inch rack compatible |
Located in Yueqing, Zhejiang—China’s low-voltage electrical capital—we bring over 18 years of specialized SMPS engineering, verified onsite by TÜV Rheinland for total peace of mind.
Rigorous screening of Japanese and Taiwanese capacitors (Rubycon, Nichicon), custom transformers, and STMicroelectronics MOSFETs.
High-speed surface-mount technology ensures micro-placement accuracy of miniature passive components and control ICs.
Multi-zone temperature profiling prevents thermal shock and guarantees void-free, crack-resistant solder joints.
Automated Optical Inspection scans 100% of boards for solder bridging, tombstoning, missing parts, and polarity misalignment.
Anti-vibration thermal adhesive potting and precision fitting into corrosion-resistant metal and aluminum enclosures.
Fine-tuning output voltage pots, verifying current limiting thresholds, and verifying ripple/noise with high-bandwidth oscilloscopes.
Dedicated high-temperature aging chambers stress every unit under 100% load for 4 to 8 hours to eliminate infant mortality.
Withstand 3000VAC primary-to-secondary isolation testing, ground continuity checks, and Swiss-ready export packaging.
Clear, direct answers addressing import compliance, custom modifications, logistics, and quality assurance.
Yes. The Swiss Ordinance on Electrical Low-Voltage Equipment (NEV / SR 734.26) aligns directly with the European Union Low Voltage Directive (2014/35/EU) and Electromagnetic Compatibility Directive (2014/30/EU). Our products carry full CE conformity documentation, meeting EN 62368-1, EN 61010-1, and EN 55032 Class B standards, satisfying Swiss Federal Heavy Current Inspectorate (ESTI) requirements.
Our metal enclosed power supplies are engineered with high-conductivity cold-rolled steel and aluminum heatsinks. With conversion efficiencies ranging between 89% and 94%, internal thermal losses are kept to a minimum. Standard models operate up to 50°C at full load with natural convection and provide smooth thermal derating up to 70°C without catastrophic shutdown.
Yes. Backed by our in-house engineering team with 5+ years of SMPS experience, we support OEM/ODM requests. This includes non-standard voltages (e.g., 36V, 60V, 72V DC), conformal silicone or polyurethane coating for moisture and condensation protection in alpine conditions, and private branding/laser-engraved labeling.
Every export shipment includes comprehensive commercial invoices with exact HS tariff codes (typically 8504.40), detailed packing lists, CE Declarations of Conformity, full RoHS/REACH compliance documentation, and factory test/burn-in reports. Onsite factory verification reports from TÜV Rheinland can also be provided upon request.
Standard catalog items such as the EDR-120, LEYU-LRS-150-24, and 240W DIN-rail units are stocked in sample quantities and dispatched within 24 to 72 hours via DHL/FedEx Express to Zurich, Geneva, or Basel (typically 3 to 5 business days transit). Custom prototype modifications generally require 7 to 14 days.
We offer flexible sampling starting at 1 piece for standard industrial DIN rail and enclosed metal models, allowing engineering evaluation on machine prototypes. For standard volume production, flexible carton-level quantities apply, while custom OEM housing or transformer projects are quoted based on specific production batches.